Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Over voltage category3
Rated insulation voltage Ui440V
Explosion-proofNo
Voltage typeAC
Rated current7A
Flush-mounted installationYes
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section multi-wired1 - 25mm²
Built-in depth60mm
Width in number of modular spacings4
Current limiting class3
Degree of protection (IP)IP20
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles4
Ambient temperature during operating-25 - 75°C
Power loss5.6W
Pollution degree2
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 25mm²
Additional equipment possibleYes
Frequency50 - 50Hz
Rated voltage240V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C7/4-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Over voltage category

3

Rated insulation voltage Ui

440V

Explosion-proof

Voltage type

AC

Rated current

7A

Flush-mounted installation

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Built-in depth

60mm

Width in number of modular spacings

4

Current limiting class

3

Degree of protection (IP)

IP20

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Ambient temperature during operating

-25 .. 75°C

Power loss

5.6W

Pollution degree

2

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Frequency

50 .. 50Hz

Rated voltage

240V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA