Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current40A
Built-in depth60mm
Voltage typeAC
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Power loss12.4W
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated voltage240V
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui440V
Current limiting class3
Pollution degree2
Frequency50 - 50Hz
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings4
Flush-mounted installationYes
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Release characteristicD
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D40/4-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

40A

Built-in depth

60mm

Voltage type

AC

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Power loss

12.4W

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated voltage

240V

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Current limiting class

3

Pollution degree

2

Frequency

50 .. 50Hz

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

4

Flush-mounted installation

Additional equipment possible

Concurrently switching neutral conductor

Release characteristic

D

Number of poles (total)

4