Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)4
Release characteristicD
Rated current40A
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC
Built-in depth60mm
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Current limiting class3
Power loss12.4W
Concurrently switching neutral conductorNo
Frequency50 - 50Hz
Flush-mounted installationYes
Pollution degree2
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Width in number of modular spacings4
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D40/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

4

Release characteristic

D

Rated current

40A

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Built-in depth

60mm

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Current limiting class

3

Power loss

12.4W

Concurrently switching neutral conductor

Frequency

50 .. 50Hz

Flush-mounted installation

Pollution degree

2

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

4

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.