Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release2 - 10A
Rated permanent current Iu250A
Overload release current setting100 - 250A
Adjustment range undelayed short-circuit release2 - 12A
Device constructionBuilt-in device plug-in technique
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Type of electrical connection of main circuitOther
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Motor drive integratedNo
With integrated under voltage releaseNo
Number of poles3
Type of control elementRocker lever
Degree of protection (IP)IP20
Position of connection for main current circuitConnection at separate chassis part
Motor drive optionalYes
With switched-off indicatorNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-PX250-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

2 .. 10A

Rated permanent current Iu

250A

Overload release current setting

100 .. 250A

Adjustment range undelayed short-circuit release

2 .. 12A

Device construction

Built-in device plug-in technique

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Type of electrical connection of main circuit

Other

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive integrated

With integrated under voltage release

Number of poles

3

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Position of connection for main current circuit

Connection at separate chassis part

Motor drive optional

With switched-off indicator

Related products