Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release2 - 10A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range undelayed short-circuit release2 - 18A
Integrated earth fault protectionNo
Overload release current setting64 - 160A
Rated voltage690 - 690V
Type of electrical connection of main circuitOther
Device constructionBuilt-in device plug-in technique
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Rated permanent current Iu160A
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Complete device with protection unitYes
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of control elementRocker lever
Degree of protection (IP)IP20
Number of poles3
Motor drive optionalYes
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS2-VX160-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

2 .. 10A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range undelayed short-circuit release

2 .. 18A

Integrated earth fault protection

Overload release current setting

64 .. 160A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Other

Device construction

Built-in device plug-in technique

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Rated permanent current Iu

160A

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Complete device with protection unit

Position of connection for main current circuit

Front side

With switched-off indicator

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Number of poles

3

Motor drive optional

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.