Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu100A
Rated voltage690 - 690V
Overload release current setting40 - 100A
Adjustment range undelayed short-circuit release2 - 12A
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Type of control elementRocker lever
Complete device with protection unitYes
Number of poles4
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-AX100

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

100A

Rated voltage

690 .. 690V

Overload release current setting

40 .. 100A

Adjustment range undelayed short-circuit release

2 .. 12A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

With integrated under voltage release

Type of control element

Rocker lever

Complete device with protection unit

Number of poles

4

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Related products