  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu100A
Integrated earth fault protectionYes
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release2 - 18A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalYes
Type of control elementRocker lever
Number of poles4
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Position of connection for main current circuitFront side
With switched-off indicatorNo
Overload release current setting40 - 100A
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Rated voltage690 - 690V
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release2 - 10A
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-VX100-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

100A

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

2 .. 18A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

Number of poles

4

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Position of connection for main current circuit

Front side

With switched-off indicator

Overload release current setting

40 .. 100A

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Adjustment range short-term delayed short-circuit release

2 .. 10A

Motor drive optional

Degree of protection (IP)

IP20