Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu160A
Adjustment range undelayed short-circuit release2 - 18A
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
Device constructionBuilt-in device plug-in technique
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitOther
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release2 - 10A
Complete device with protection unitYes
With integrated under voltage releaseNo
Overload release current setting64 - 160A
Position of connection for main current circuitFront side
Type of control elementRocker lever
Number of poles4
Motor drive integratedNo
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-VX160/VAR-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Adjustment range undelayed short-circuit release

2 .. 18A

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

Device construction

Built-in device plug-in technique

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Other

With switched-off indicator

Adjustment range short-term delayed short-circuit release

2 .. 10A

Complete device with protection unit

With integrated under voltage release

Overload release current setting

64 .. 160A

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Number of poles

4

Motor drive integrated

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.