Technical specifications

Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release2 - 12A
Rated permanent current Iu160A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Motor drive integratedNo
Integrated earth fault protectionNo
Overload release current setting64 - 160A
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of poles4
Adjustment range short-term delayed short-circuit release0 - 0A
Type of control elementRocker lever
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-AX160

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

2 .. 12A

Rated permanent current Iu

160A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

With integrated under voltage release

Degree of protection (IP)

IP20

Motor drive integrated

Integrated earth fault protection

Overload release current setting

64 .. 160A

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of poles

4

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of control element

Rocker lever

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive optional

Related products