Technical specifications

Rated permanent current Iu160A
Rated voltage690 - 690V
Overload release current setting64 - 160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release2 - 10A
Type of electrical connection of main circuitScrew connection
Number of poles4
Adjustment range undelayed short-circuit release2 - 18A
Complete device with protection unitYes
With integrated under voltage releaseNo
With switched-off indicatorNo
Motor drive integratedNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-VX160/VAR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Rated voltage

690 .. 690V

Overload release current setting

64 .. 160A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

2 .. 10A

Type of electrical connection of main circuit

Screw connection

Number of poles

4

Adjustment range undelayed short-circuit release

2 .. 18A

Complete device with protection unit

With integrated under voltage release

With switched-off indicator

Motor drive integrated

Motor drive optional

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection