Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu160A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release2 - 10A
Overload release current setting64 - 160A
Adjustment range undelayed short-circuit release2 - 18A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device plug-in technique
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitOther
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of poles4
Type of control elementRocker lever
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-VX160/VAR-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

2 .. 10A

Overload release current setting

64 .. 160A

Adjustment range undelayed short-circuit release

2 .. 18A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

DIN rail (top hat rail) mounting optional

Device construction

Built-in device plug-in technique

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of poles

4

Type of control element

Rocker lever

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.