Rated permanent current Iu160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Overload release current setting64 - 160A
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release2 - 10A
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
With integrated under voltage releaseNo
Integrated earth fault protectionYes
Number of poles4
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release2 - 18A
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Motor drive integratedNo
Rated voltage690 - 690V
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-VX160-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Overload release current setting

64 .. 160A

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

2 .. 10A

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

With integrated under voltage release

Integrated earth fault protection

Number of poles

4

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

2 .. 18A

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Motor drive integrated

Rated voltage

690 .. 690V