

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range short-term delayed short-circuit release
2 - 10A
Rated permanent current Iu
250A
Adjustment range undelayed short-circuit release
2 - 12A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
Yes
Overload release current setting
100 - 250A
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Frame clamp
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
Suitable for DIN rail (top hat rail) mounting
No
With integrated under voltage release
No
Type of control element
Rocker lever
Degree of protection (IP)
IP20
Complete device with protection unit
Yes
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Position of connection for main current circuit
Front side
Number of poles
4
From same serie
NZMN2-4-VX250-BT

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range short-term delayed short-circuit release
2 .. 10A
Rated permanent current Iu
250A
Adjustment range undelayed short-circuit release
2 .. 12A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Overload release current setting
100 .. 250A
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Frame clamp
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Suitable for DIN rail (top hat rail) mounting
With integrated under voltage release
Type of control element
Rocker lever
Degree of protection (IP)
IP20
Complete device with protection unit
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Position of connection for main current circuit
Front side
Number of poles
4
From same serie
We use cookies to enhance your experience.