Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth69.5mm
Over voltage category3
Surge current capacity0.25kA
Rated fault current0.03A
Voltage typeAC
Release characteristicB
Rated short-circuit breaking capacity according to IEC 60947-20kA
Frequency50 Hz
Rated insulation voltage Ui500V
Rated voltage230V
Pollution degree2
Degree of protection (IP)IP20
Rated current10A
Current limiting class3
Width in number of modular spacings2
Concurrently switching neutral conductorYes
Leakage current typeAC
Number of protected poles1
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-B10/1N/003-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

69.5mm

Over voltage category

3

Surge current capacity

0.25kA

Rated fault current

0.03A

Voltage type

AC

Release characteristic

B

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Frequency

50 Hz

Rated insulation voltage Ui

500V

Rated voltage

230V

Pollution degree

2

Degree of protection (IP)

IP20

Rated current

10A

Current limiting class

3

Width in number of modular spacings

2

Concurrently switching neutral conductor

Leakage current type

AC

Number of protected poles

1

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version