Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationNo
Rated current16A
Width in number of modular spacings2
Built-in depth69.5mm
Rated voltage230V
Release characteristicB
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Number of poles (total)2
Current limiting class3
Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorYes
Over voltage category3
Frequency50 Hz
Leakage current typeAC
With interlocking deviceNo
Surge current capacity0.25kA
Anti-nuisance tripping versionNo
Rated fault current0.03A
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-B16/1N/003

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

16A

Width in number of modular spacings

2

Built-in depth

69.5mm

Rated voltage

230V

Release characteristic

B

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Current limiting class

3

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Over voltage category

3

Frequency

50 Hz

Leakage current type

AC

With interlocking device

Surge current capacity

0.25kA

Anti-nuisance tripping version

Rated fault current

0.03A

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

From same serie

Recommended products