Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current10A
Rated voltage230V
Voltage typeAC
Release characteristicC
Built-in depth69.5mm
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section solid-core1 - 25mm²
Rated fault current0.03A
Leakage current typeAC
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Width in number of modular spacings2
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)2
Rated insulation voltage Ui500V
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Anti-nuisance tripping versionNo
Over voltage category3
Surge current capacity0.25kA
Frequency50 Hz
Number of protected poles1
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to EN 610096kA
Pollution degree2
Current limiting class3

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-C10/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

10A

Rated voltage

230V

Voltage type

AC

Release characteristic

C

Built-in depth

69.5mm

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Rated fault current

0.03A

Leakage current type

AC

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

2

Rated insulation voltage Ui

500V

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Anti-nuisance tripping version

Over voltage category

3

Surge current capacity

0.25kA

Frequency

50 Hz

Number of protected poles

1

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to EN 61009

6kA

Pollution degree

2

Current limiting class

3