Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Related products
EMS2-ROSF-Z-9-24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Height
160mm
Width
22.5mm
Number of auxiliary contacts as normally closed contact
1
Depth
114.5mm
Power consumption
13W
Number of command positions
0
Rated operation power at AC-3, 400 V
3kW
Rated operation current Ie
9A
Number of auxiliary contacts as normally open contact
1
With transformer
Suitable for emergency stop
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for CAN
Overload release current setting
1.5 .. 9A
Number of indicator lights
0
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
External reset possible
Supporting protocol for Data-Highway
Rail mounting possible
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for INTERBUS
With short-circuit release
Release class
CLASS 10 A
Type of electrical connection of main circuit
Screw connection
With fuse
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Degree of protection (IP)
IP20
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Supporting protocol for EtherNet/IP
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for PROFIsafe
Rated power, 460 V, 60 Hz, 3-phase
0kW
Type of motor starter
Reversing starter
Ambient temperature, upper operating limit
70°C
Rated operation current at AC-3, 400 V
7A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 400 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A