Technical specifications
EMS2-DO-Z-2,4-230VAC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With transformer
Power consumption
4.7W
Depth
114.5mm
Width
22.5mm
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 400 V
0.75kW
Height
99mm
Number of command positions
0
Number of auxiliary contacts as normally open contact
1
Supporting protocol for other bus systems
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Suitable for emergency stop
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for LON
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Number of indicator lights
0
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Supporting protocol for DeviceNet
Degree of protection (IP)
IP20
Rail mounting possible
External reset possible
Supporting protocol for Modbus
Supporting protocol for ASI
Overload release current setting
0.18 .. 3A
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for CAN
Rated operation current Ie
2.4A
Release class
CLASS 10
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
With short-circuit release
With fuse
Rated conditional short-circuit current, type 2, 400 V
0A
Type of electrical connection of main circuit
Screw connection
Supporting protocol for SafetyBUS p
Supporting protocol for AS-Interface Safety at Work
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Voltage type for actuating
AC
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Type of motor starter
Direct online starter (DOL)
Degree of protection (NEMA)
Other
Supporting protocol for PROFIsafe
Rated operation current at AC-3, 400 V
2.4A
Rated conditional short-circuit current, type 2, 230 V
0A
Ambient temperature, upper operating limit
70°C
Temperature compensated overload protection
Supporting protocol for PROFINET CBA
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for PROFINET IO
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for Foundation Fieldbus
Rated operation power at AC-3, 230 V, 3-phase
0.37kW