Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Related products
EMS2-DO-T-2,4-24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
22.5mm
Height
99mm
Depth
114.5mm
Overload release current setting
0.18 .. 3A
With transformer
Number of auxiliary contacts as normally open contact
1
Supporting protocol for PROFIBUS
Suitable for emergency stop
Power consumption
3.3W
Rated operation power at AC-3, 400 V
0.75kW
Supporting protocol for TCP/IP
Supporting protocol for CAN
Rated operation current Ie
2.4A
Number of auxiliary contacts as normally closed contact
1
Supporting protocol for LON
Number of command positions
0
Supporting protocol for ASI
Supporting protocol for INTERBUS
Number of indicator lights
0
Supporting protocol for Modbus
Release class
CLASS 10
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for Data-Highway
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
External reset possible
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for INTERBUS-Safety
Rail mounting possible
Supporting protocol for SERCOS
Supporting protocol for other bus systems
With fuse
With short-circuit release
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Supporting protocol for SafetyBUS p
Ambient temperature, upper operating limit
70°C
Rated power, 460 V, 60 Hz, 3-phase
0kW
Degree of protection (NEMA)
Other
Voltage type for actuating
DC
Type of motor starter
Direct online starter (DOL)
Temperature compensated overload protection
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated conditional short-circuit current, type 2, 400 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current at AC-3, 400 V
2.4A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Coordination class according to IEC 60947-4-3
Class 1