Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height99mm
Depth114.5mm
Number of auxiliary contacts as normally closed contact1
Rated operation power at AC-3, 400 V0.75kW
Number of command positions0
Power consumption3.3W
Width22.5mm
Rated operation current Ie2.4A
Number of indicator lights0
With transformerNo
Number of auxiliary contacts as normally open contact1
Overload release current setting0.18 - 3A
Suitable for emergency stopNo
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Rail mounting possibleYes
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for EtherNet/IPNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Type of electrical connection of main circuitScrew connection
Type of electrical connection for auxiliary- and control current circuitScrew connection
External reset possibleNo
Release classCLASS 10
Supporting protocol for AS-Interface Safety at WorkNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Degree of protection (IP)IP20
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
With fuseNo
With short-circuit releaseNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V0A
Type of motor starterDirect online starter (DOL)
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V2.4A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EMS2-DO-Z-2,4-24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

99mm

Depth

114.5mm

Number of auxiliary contacts as normally closed contact

1

Rated operation power at AC-3, 400 V

0.75kW

Number of command positions

0

Power consumption

3.3W

Width

22.5mm

Rated operation current Ie

2.4A

Number of indicator lights

0

With transformer

Number of auxiliary contacts as normally open contact

1

Overload release current setting

0.18 .. 3A

Suitable for emergency stop

Supporting protocol for TCP/IP

Supporting protocol for LON

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for ASI

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Rail mounting possible

Supporting protocol for Data-Highway

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

External reset possible

Release class

CLASS 10

Supporting protocol for AS-Interface Safety at Work

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

With fuse

With short-circuit release

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Temperature compensated overload protection

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

0A

Type of motor starter

Direct online starter (DOL)

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

2.4A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.