Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height99mm
Number of auxiliary contacts as normally closed contact1
Power consumption14.6W
Number of auxiliary contacts as normally open contact1
With transformerNo
Width22.5mm
Number of command positions0
Depth114.5mm
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Suitable for emergency stopNo
Number of indicator lights0
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SERCOSNo
External reset possibleNo
Rail mounting possibleYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Release classCLASS 10 A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Type of electrical connection of main circuitScrew connection
Supporting protocol for EtherNet/IPNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for Foundation FieldbusNo
With short-circuit releaseNo
Supporting protocol for PROFINET IONo
With fuseNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Ambient temperature, upper operating limit70°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 1
Rated operation power at AC-3, 400 V3kW
Rated operation current Ie9A
Overload release current setting1.5 - 9A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V6.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user