Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LONNo
Power consumption2.5W
Width22.5mm
Height99mm
Number of indicator lights0
Suitable for emergency stopNo
With transformerNo
Supporting protocol for TCP/IPNo
Depth114.5mm
Overload release current setting0.18 - 3A
Number of auxiliary contacts as normally closed contact1
Rated operation power at AC-3, 400 V1.1kW
Number of command positions0
Rated operation current Ie3A
Number of auxiliary contacts as normally open contact1
Supporting protocol for ModbusNo
Rail mounting possibleYes
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsNo
With short-circuit releaseNo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
External reset possibleNo
Supporting protocol for PROFIBUSNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
With fuseNo
Supporting protocol for Data-HighwayNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Release classCLASS 10
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V3A
Ambient temperature, upper operating limit70°C
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 2, 230 V0A
Voltage type for actuatingDC
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V0A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase0.55kW
Temperature compensated overload protectionYes
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EMS2-DOS-T-3-24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Supporting protocol for LON

Power consumption

2.5W

Width

22.5mm

Height

99mm

Number of indicator lights

0

Suitable for emergency stop

With transformer

Supporting protocol for TCP/IP

Depth

114.5mm

Overload release current setting

0.18 .. 3A

Number of auxiliary contacts as normally closed contact

1

Rated operation power at AC-3, 400 V

1.1kW

Number of command positions

0

Rated operation current Ie

3A

Number of auxiliary contacts as normally open contact

1

Supporting protocol for Modbus

Rail mounting possible

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for other bus systems

With short-circuit release

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

External reset possible

Supporting protocol for PROFIBUS

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

With fuse

Supporting protocol for Data-Highway

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Release class

CLASS 10

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

3A

Ambient temperature, upper operating limit

70°C

Supporting protocol for PROFINET CBA

Rated conditional short-circuit current, type 2, 230 V

0A

Voltage type for actuating

DC

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

0A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.55kW

Temperature compensated overload protection

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A