Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
Related products
EMS2-DOS-T-3-24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Supporting protocol for LON
Power consumption
2.5W
Width
22.5mm
Height
99mm
Number of indicator lights
0
Suitable for emergency stop
With transformer
Supporting protocol for TCP/IP
Depth
114.5mm
Overload release current setting
0.18 .. 3A
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 400 V
1.1kW
Number of command positions
0
Rated operation current Ie
3A
Number of auxiliary contacts as normally open contact
1
Supporting protocol for Modbus
Rail mounting possible
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for other bus systems
With short-circuit release
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS-Safety
External reset possible
Supporting protocol for PROFIBUS
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for SERCOS
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
With fuse
Supporting protocol for Data-Highway
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Release class
CLASS 10
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of motor starter
Direct online starter (DOL)
Rated operation current at AC-3, 400 V
3A
Ambient temperature, upper operating limit
70°C
Supporting protocol for PROFINET CBA
Rated conditional short-circuit current, type 2, 230 V
0A
Voltage type for actuating
DC
Coordination class according to IEC 60947-4-3
Class 1
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.55kW
Temperature compensated overload protection
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe