Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height99mm
Width22.5mm
Power consumption12W
With transformerNo
Depth114.5mm
Rated operation power at AC-3, 400 V3kW
Number of auxiliary contacts as normally closed contact1
Number of command positions0
Supporting protocol for LONNo
External reset possibleNo
Number of auxiliary contacts as normally open contact1
Rated operation current Ie9A
Overload release current setting1.5 - 9A
Supporting protocol for ASINo
Rated control supply voltage Us at AC 50HZ0 - 0V
Number of indicator lights0
Supporting protocol for ModbusNo
Supporting protocol for other bus systemsNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Rail mounting possibleYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10
Type of electrical connection of main circuitSpring clamp connection
With fuseNo
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Supporting protocol for SafetyBUS pNo
Ambient temperature, upper operating limit70°C
With short-circuit releaseNo
Supporting protocol for EtherNet/IPNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated operation current at AC-3, 400 V7A
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Rated power, 460 V, 60 Hz, 3-phase0kW
Type of motor starterDirect online starter (DOL)
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for INTERBUS-SafetyNo
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V0A
Supporting protocol for PROFINET IONo
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Coordination class according to IEC 60947-4-3Class 1

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EMS2-DOS-T-9-24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

99mm

Width

22.5mm

Power consumption

12W

With transformer

Depth

114.5mm

Rated operation power at AC-3, 400 V

3kW

Number of auxiliary contacts as normally closed contact

1

Number of command positions

0

Supporting protocol for LON

External reset possible

Number of auxiliary contacts as normally open contact

1

Rated operation current Ie

9A

Overload release current setting

1.5 .. 9A

Supporting protocol for ASI

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Number of indicator lights

0

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for DeviceNet

Rail mounting possible

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Suitable for emergency stop

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

Release class

CLASS 10

Type of electrical connection of main circuit

Spring clamp connection

With fuse

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Supporting protocol for SafetyBUS p

Ambient temperature, upper operating limit

70°C

With short-circuit release

Supporting protocol for EtherNet/IP

Rated power, 575 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated operation current at AC-3, 400 V

7A

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rated power, 460 V, 60 Hz, 3-phase

0kW

Type of motor starter

Direct online starter (DOL)

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

0A

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.