Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
EMS2-ROS-Z-9-24VDC

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Depth
114.5mm
Width
22.5mm
Height
99mm
Number of auxiliary contacts as normally open contact
1
Number of command positions
0
With transformer
Rated operation power at AC-3, 400 V
3kW
Number of auxiliary contacts as normally closed contact
1
Power consumption
12W
Supporting protocol for LON
Number of indicator lights
0
Overload release current setting
1.5 .. 9A
Rated operation current Ie
9A
Suitable for emergency stop
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for SUCONET
Supporting protocol for other bus systems
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rail mounting possible
Degree of protection (IP)
IP20
Release class
CLASS 10 A
Supporting protocol for INTERBUS-Safety
With short-circuit release
With fuse
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for SERCOS
External reset possible
Type of electrical connection of main circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Type of motor starter
Reversing starter
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Supporting protocol for PROFINET IO
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for PROFINET CBA
Voltage type for actuating
DC
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Ambient temperature, upper operating limit
70°C
Rated conditional short-circuit current, type 2, 400 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
0A
Temperature compensated overload protection
Rated operation current at AC-3, 400 V
7A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Degree of protection (NEMA)
Other
Coordination class according to IEC 60947-4-3
Class 1