Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height99mm
With transformerNo
Width22.5mm
Depth114.5mm
Number of auxiliary contacts as normally open contact0
Overload release current setting1.5 - 9A
Supporting protocol for ModbusNo
Rated operation current Ie9A
Rated operation power at AC-3, 400 V3kW
External reset possibleNo
Supporting protocol for ASINo
Rail mounting possibleYes
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for CANNo
Supporting protocol for LONNo
Number of indicator lights5
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Number of command positions-
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
With short-circuit releaseNo
Voltage type for actuatingDC
Supporting protocol for Foundation FieldbusNo
Type of electrical connection of main circuitSpring clamp connection
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for DeviceNet SafetyNo
Ambient temperature, upper operating limit55°C
Rated operation current at AC-3, 400 V7A
Release classCLASS 10 A
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Supporting protocol for INTERBUS-SafetyNo
With fuseNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Type of motor starterReversing starter
Supporting protocol for SafetyBUS pNo
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V0A
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EMS2-ROS-T-9-SWD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Height

99mm

With transformer

Width

22.5mm

Depth

114.5mm

Number of auxiliary contacts as normally open contact

0

Overload release current setting

1.5 .. 9A

Supporting protocol for Modbus

Rated operation current Ie

9A

Rated operation power at AC-3, 400 V

3kW

External reset possible

Supporting protocol for ASI

Rail mounting possible

Suitable for emergency stop

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for CAN

Supporting protocol for LON

Number of indicator lights

5

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Number of command positions

-

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With short-circuit release

Voltage type for actuating

DC

Supporting protocol for Foundation Fieldbus

Type of electrical connection of main circuit

Spring clamp connection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for DeviceNet Safety

Ambient temperature, upper operating limit

55°C

Rated operation current at AC-3, 400 V

7A

Release class

CLASS 10 A

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Supporting protocol for INTERBUS-Safety

With fuse

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Type of motor starter

Reversing starter

Supporting protocol for SafetyBUS p

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

0A

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Related products