Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth114.5mm
Height99mm
Width22.5mm
With transformerNo
Rated operation current Ie9A
Number of auxiliary contacts as normally open contact1
Rated operation power at AC-3, 400 V3kW
Power consumption14.6W
Number of command positions0
Suitable for emergency stopNo
Number of indicator lights0
Number of auxiliary contacts as normally closed contact1
Supporting protocol for CANNo
Supporting protocol for LONNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Overload release current setting1.5 - 9A
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rail mounting possibleYes
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for SUCONETNo
External reset possibleNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for SERCOSNo
With short-circuit releaseNo
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10 A
With fuseNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 2, 400 V0A
Voltage type for actuatingDC
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V6.5A
Type of motor starterReversing starter
Temperature compensated overload protectionYes
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Ambient temperature, upper operating limit70°C
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 480 Y/277 V0A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EMS2-RO-T-9-24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

114.5mm

Height

99mm

Width

22.5mm

With transformer

Rated operation current Ie

9A

Number of auxiliary contacts as normally open contact

1

Rated operation power at AC-3, 400 V

3kW

Power consumption

14.6W

Number of command positions

0

Suitable for emergency stop

Number of indicator lights

0

Number of auxiliary contacts as normally closed contact

1

Supporting protocol for CAN

Supporting protocol for LON

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Overload release current setting

1.5 .. 9A

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rail mounting possible

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for SUCONET

External reset possible

Supporting protocol for INTERBUS-Safety

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for SERCOS

With short-circuit release

Supporting protocol for AS-Interface Safety at Work

Release class

CLASS 10 A

With fuse

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Rated conditional short-circuit current, type 2, 400 V

0A

Voltage type for actuating

DC

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

6.5A

Type of motor starter

Reversing starter

Temperature compensated overload protection

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Ambient temperature, upper operating limit

70°C

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Degree of protection (NEMA)

Other

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Related products