Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth114.5mm
With transformerNo
Height99mm
Rated operation power at AC-3, 400 V3kW
Power consumption12W
Width22.5mm
Overload release current setting1.5 - 9A
Supporting protocol for ASINo
Number of auxiliary contacts as normally closed contact0
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Number of auxiliary contacts as normally open contact0
Suitable for emergency stopNo
Number of command positions0
Rated operation current Ie9A
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
External reset possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleYes
Supporting protocol for CANNo
Supporting protocol for other bus systemsYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Release classCLASS 10 A
Supporting protocol for SafetyBUS pNo
With short-circuit releaseNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Rated power, 575 V, 60 Hz, 3-phase0kW
Ambient temperature, upper operating limit55°C
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Type of motor starterReversing starter
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
With fuseNo
Rated conditional short-circuit current, type 2, 400 V0A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V0A
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for AS-Interface Safety at WorkNo
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for PROFIsafeNo
Rated operation current at AC-3, 400 V6.5A
Voltage type for actuatingDC
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 1

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EMS2-RO-T-9-SWD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

114.5mm

With transformer

Height

99mm

Rated operation power at AC-3, 400 V

3kW

Power consumption

12W

Width

22.5mm

Overload release current setting

1.5 .. 9A

Supporting protocol for ASI

Number of auxiliary contacts as normally closed contact

0

Number of indicator lights

0

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for LON

Number of auxiliary contacts as normally open contact

0

Suitable for emergency stop

Number of command positions

0

Rated operation current Ie

9A

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for DeviceNet

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Supporting protocol for CAN

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Release class

CLASS 10 A

Supporting protocol for SafetyBUS p

With short-circuit release

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Type of motor starter

Reversing starter

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

With fuse

Rated conditional short-circuit current, type 2, 400 V

0A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

0A

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for AS-Interface Safety at Work

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Supporting protocol for PROFIsafe

Rated operation current at AC-3, 400 V

6.5A

Voltage type for actuating

DC

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 1

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.