Technical specifications
Related products
EASY-E4-DC-6AE1

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- EATON
Technical specifications
Expandable
Depth
58mm
With display
With time switch clock
Width
36mm
Suitable for safety functions
Height
90mm
Switching current
0A
Power consumption
2.5W
Voltage type of supply voltage
DC
Number of analogue inputs
4
Number of analogue outputs
2
Supporting protocol for LON
Number of digital inputs
0
Number of digital outputs
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
With optical interface
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Supporting protocol for TCP/IP
Number of HW-interfaces RS-485
0
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for CAN
With relay output
Supporting protocol for SUCONET
Explosion safety category for gas
None
Rail mounting possible
Redundancy
Supporting protocol for DeviceNet
Explosion safety category for dust
None
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Appendant operation agent (Ex ib)
Number of HW-interfaces Wireless
0
Supporting protocol for SERCOS
Appendant operation agent (Ex ia)
Rack-assembly possible
Supporting protocol for INTERBUS-Safety
Degree of protection (IP)
IP20
Expansion device
Number of interfaces PROFINET
0
Radio standard Bluetooth
Wall mounting/direct mounting
Supporting protocol for PROFINET IO
Radio standard Wi-Fi 802.11
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Supply voltage AC 50 Hz
0 .. 0V
Performance level according to EN ISO 13849-1
None
IO link master
Basic device
Front built-in possible
Supporting protocol for Foundation Fieldbus
Supply voltage DC
20.4 .. 28.8V
Certified for UL hazardous location division 2
Certified for UL hazardous location class II
Radio standard GPRS
Certified for UL hazardous location class I
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location group D (propane)
Supply voltage AC 60 Hz
0 .. 0V
Certified for UL hazardous location group C (ethylene)
Radio standard GSM
Radio standard UMTS
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group A (acetylene)
SIL according to IEC 61508
None
Certified for UL hazardous location group G (non-conductive dusts)
Supporting protocol for EtherCAT
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group B (hydrogen)