Number of contact energized outputs with signalling function0
CascadableNo
Explosion safety category for dustNone
Number of semiconductor outputs with signalling function1
Voltage typeDC
Rated control supply voltage Us at AC 60HZ0 - 0V
Type of interface for safety communicationNone
Rated control supply voltage Us at AC 50HZ0 - 0V
Number of protected semiconductor outputs0
Suitable for safety functionsNo
Material housingMetal
Switching frequency600Hz
Explosion safety category for gasNone
Coating housingOther
Number of protected contact energized outputs0
Rated control supply voltage Us at DC10 - 30V
Type of switch functionNormally open contact
Type of electric connectionCable
With monitoring function downstream switching devicesNo
Construction type housingCylinder, screw-thread
Mechanical mounting condition for sensorConcise
Max. output current at protected output0mA
Type of interfaceNone
Category according to EN 954-1B
Type of actuationMetallic Target
Performance level according to EN ISO 13849-1None
SIL according to IEC 61508None
Compression-resistantNo
Switching distance10mm
Type of switching outputPNP
Supply voltage10 - 30V
Width sensor0mm
Diameter sensor30mm
Height of sensor0mm
Length of sensor67.7mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as
Alongside the essential cookies this site needs to work, with your consent we also use analytics and advertising cookies — to measure traffic and to show personalised ads. That data is processed by Google (Google Analytics), Microsoft (Clarity) and Meta (Meta Pixel). You can change your choice at any time under “Cookie settings” in the footer. More in our Cookie policy