Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Yes
Version as emergency stop installation
Yes
Version as reversing switch
No
Rated permanent current at AC-23, 400 V
32A
Rated permanent current at AC-21, 400 V
32A
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Yes
Number of switches
1
Rated permanent current Iu
32A
Version as safety switch
No
Rated operation power at AC-3, 400 V
13kW
Number of poles
3
Rated short-time withstand current lcw
0.64kA
Rated operating voltage
690 - 690V
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
1
Device construction
Complete device in housing
Voltage release optional
No
Switching power at 400 V
15kW
Conditioned rated short-circuit current Iq
80kA
Suitable for floor mounting
Yes
Rated operation power at AC-23, 400 V
15kW
Suitable for distribution board installation
No
Motor drive optional
No
Number of auxiliary contacts as normally closed contact
1
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Motor drive integrated
No
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
Interlockable
Yes
Suitable for intermediate mounting
No
With pre-assembled cabling
No
Degree of protection (NEMA)
12
Width
100mm
Colour control element
Red
Type of electrical connection of main circuit
Screw connection
Depth
115mm
Height
180mm
P1-32/I2/SVB/HI11-NA

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as emergency stop installation
Version as reversing switch
Rated permanent current at AC-23, 400 V
32A
Rated permanent current at AC-21, 400 V
32A
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Number of switches
1
Rated permanent current Iu
32A
Version as safety switch
Rated operation power at AC-3, 400 V
13kW
Number of poles
3
Rated short-time withstand current lcw
0.64kA
Rated operating voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
1
Device construction
Complete device in housing
Voltage release optional
Switching power at 400 V
15kW
Conditioned rated short-circuit current Iq
80kA
Suitable for floor mounting
Rated operation power at AC-23, 400 V
15kW
Suitable for distribution board installation
Motor drive optional
Number of auxiliary contacts as normally closed contact
1
Suitable for front mounting centre
Suitable for front mounting 4-hole
Motor drive integrated
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
Interlockable
Suitable for intermediate mounting
With pre-assembled cabling
Degree of protection (NEMA)
12
Width
100mm
Colour control element
Red
Type of electrical connection of main circuit
Screw connection
Depth
115mm
Height
180mm