Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Yes
Rated permanent current at AC-21, 400 V
63A
Version as maintenance-/service switch
Yes
Number of switches
1
Version as reversing switch
No
Rated operation power at AC-3, 400 V
30kW
Version as emergency stop installation
No
Rated short-time withstand current lcw
1.26kA
Rated permanent current at AC-23, 400 V
63A
Number of auxiliary contacts as normally open contact
0
Conditioned rated short-circuit current Iq
100kA
Number of auxiliary contacts as normally closed contact
0
Version as safety switch
No
Number of poles
3
Max. rated operation voltage Ue AC
690V
Switching power at 400 V
30kW
Motor drive optional
No
Rated permanent current Iu
63A
Suitable for front mounting centre
No
Type of control element
Door coupling rotary drive
Suitable for floor mounting
Yes
Device construction
Complete device in housing
Voltage release optional
No
Interlockable
Yes
Rated operating voltage
690 - 690V
Number of auxiliary contacts as change-over contact
0
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Colour control element
Black
Motor drive integrated
No
Rated operation power at AC-23, 400 V
30kW
Suitable for front mounting 4-hole
No
Width
200mm
Height
155mm
Degree of protection (IP), front side
IP65
With pre-assembled cabling
No
Depth
250mm
Degree of protection (NEMA)
12
Type of electrical connection of main circuit
Screw connection
From same serie
P3-63/SE3/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Rated permanent current at AC-21, 400 V
63A
Version as maintenance-/service switch
Number of switches
1
Version as reversing switch
Rated operation power at AC-3, 400 V
30kW
Version as emergency stop installation
Rated short-time withstand current lcw
1.26kA
Rated permanent current at AC-23, 400 V
63A
Number of auxiliary contacts as normally open contact
0
Conditioned rated short-circuit current Iq
100kA
Number of auxiliary contacts as normally closed contact
0
Version as safety switch
Number of poles
3
Max. rated operation voltage Ue AC
690V
Switching power at 400 V
30kW
Motor drive optional
Rated permanent current Iu
63A
Suitable for front mounting centre
Type of control element
Door coupling rotary drive
Suitable for floor mounting
Device construction
Complete device in housing
Voltage release optional
Interlockable
Rated operating voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
0
Suitable for distribution board installation
Suitable for intermediate mounting
Colour control element
Black
Motor drive integrated
Rated operation power at AC-23, 400 V
30kW
Suitable for front mounting 4-hole
Width
200mm
Height
155mm
Degree of protection (IP), front side
IP65
With pre-assembled cabling
Depth
250mm
Degree of protection (NEMA)
12
Type of electrical connection of main circuit
Screw connection
From same serie