Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Width in number of modular spacings1
Frequency50 - 60Hz
Rated current25A
Built-in depth44mm
Rated voltage230V
Degree of protection (IP)IP20
Voltage typeAC
Pollution degree3
Number of protected poles1
Release characteristicB
Rated insulation voltage Ui440V
Over voltage category3
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)1
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-B25/1-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Width in number of modular spacings

1

Frequency

50 .. 60Hz

Rated current

25A

Built-in depth

44mm

Rated voltage

230V

Degree of protection (IP)

IP20

Voltage type

AC

Pollution degree

3

Number of protected poles

1

Release characteristic

B

Rated insulation voltage Ui

440V

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

1

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.