Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth44mm
Release characteristicB
Frequency50 - 60Hz
Voltage typeAC
Rated current20A
Rated voltage230V
Suitable for flush-mounted installationYes
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Number of protected poles3
Connectable conductor cross section solid-core1 - 25mm²
Current limiting class3
Over voltage category3
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree3
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-B20/3-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

44mm

Release characteristic

B

Frequency

50 .. 60Hz

Voltage type

AC

Rated current

20A

Rated voltage

230V

Suitable for flush-mounted installation

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Number of protected poles

3

Connectable conductor cross section solid-core

1 .. 25mm²

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

3

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.