Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current20A
Release characteristicC
Built-in depth44mm
Voltage typeAC
Frequency50 - 60Hz
Rated voltage230V
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Number of protected poles1
Over voltage category3
Current limiting class3
Pollution degree3
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Suitable for flush-mounted installationYes
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-C20/1-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

20A

Release characteristic

C

Built-in depth

44mm

Voltage type

AC

Frequency

50 .. 60Hz

Rated voltage

230V

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Number of protected poles

1

Over voltage category

3

Current limiting class

3

Pollution degree

3

Width in number of modular spacings

1

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.