Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Rated current63A
Frequency50 - 60Hz
Rated voltage230V
Voltage typeAC
Current limiting class3
Rated insulation voltage Ui440V
Built-in depth44mm
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Over voltage category3
Suitable for flush-mounted installationYes
Number of poles (total)3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 75°C
Number of protected poles3
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Width in number of modular spacings3
Pollution degree3

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-C63/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Rated current

63A

Frequency

50 .. 60Hz

Rated voltage

230V

Voltage type

AC

Current limiting class

3

Rated insulation voltage Ui

440V

Built-in depth

44mm

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Over voltage category

3

Suitable for flush-mounted installation

Number of poles (total)

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 75°C

Number of protected poles

3

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Width in number of modular spacings

3

Pollution degree

3

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.