Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-D-10-M9(230V50HZ)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Depth
95mm
Height
180mm
With transformer
Power consumption
1.4W
Number of command positions
0
Suitable for emergency stop
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-3, 400 V
4kW
Number of auxiliary contacts as normally open contact
1
Rated operation current Ie
8.5A
Overload release current setting
6.3 .. 10A
Number of indicator lights
0
Supporting protocol for TCP/IP
Supporting protocol for LON
Rail mounting possible
Supporting protocol for CAN
Supporting protocol for Modbus
Rated control supply voltage Us at AC 50HZ
230 .. 230V
External reset possible
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for other bus systems
With fuse
Rated control supply voltage Us at DC
0 .. 0V
Degree of protection (IP)
IP20
With short-circuit release
Supporting protocol for INTERBUS-Safety
Release class
CLASS 10 A
Type of electrical connection of main circuit
Screw connection
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFINET IO
Supporting protocol for SafetyBUS p
Voltage type for actuating
AC
Type of motor starter
Direct online starter (DOL)
Supporting protocol for PROFINET CBA
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Supporting protocol for PROFIsafe
Rated power, 575 V, 60 Hz, 3-phase
0kW
Temperature compensated overload protection
Supporting protocol for AS-Interface Safety at Work
Rated conditional short-circuit current, type 2, 400 V
150A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Ambient temperature, upper operating limit
55°C
Rated operation current at AC-3, 400 V
9A
Degree of protection (NEMA)
Other
Coordination class according to IEC 60947-4-3
Class 1
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A