Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Switching power at 400 V-kW
Version as reversing switchNo
Number of switches1
Version as maintenance-/service switchNo
Max. rated operation voltage Ue AC690V
Version as main switchNo
Rated operation power at AC-3, 400 V0kW
Rated short-time withstand current lcw36kA
Number of auxiliary contacts as normally closed contact0
Rated permanent current at AC-23, 400 V630A
Rated operating voltage690 - 690V
Rated operation power at AC-23, 400 V375kW
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current at AC-21, 400 V630A
Suitable for floor mountingNo
Motor drive integratedNo
Motor drive optionalNo
Version as emergency stop installationNo
Suitable for intermediate mountingNo
Conditioned rated short-circuit current Iq100kA
Suitable for front mounting 4-holeNo
Number of poles4
Suitable for distribution board installationNo
Colour control elementOther
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu630A
Version as safety switchNo
Voltage release optionalNo
Suitable for front mounting centreNo
Width390mm
Depth370mm
Degree of protection (NEMA)Other
Height125mm
Type of electrical connection of main circuitScrew connection
InterlockableNo
With pre-assembled cablingNo
Type of control elementLong turning handle
Degree of protection (IP), front sideIP00
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DMV-630N/1+SH

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Switching power at 400 V

-kW

Version as reversing switch

Number of switches

1

Version as maintenance-/service switch

Max. rated operation voltage Ue AC

690V

Version as main switch

Rated operation power at AC-3, 400 V

0kW

Rated short-time withstand current lcw

36kA

Number of auxiliary contacts as normally closed contact

0

Rated permanent current at AC-23, 400 V

630A

Rated operating voltage

690 .. 690V

Rated operation power at AC-23, 400 V

375kW

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current at AC-21, 400 V

630A

Suitable for floor mounting

Motor drive integrated

Motor drive optional

Version as emergency stop installation

Suitable for intermediate mounting

Conditioned rated short-circuit current Iq

100kA

Suitable for front mounting 4-hole

Number of poles

4

Suitable for distribution board installation

Colour control element

Other

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

630A

Version as safety switch

Voltage release optional

Suitable for front mounting centre

Width

390mm

Depth

370mm

Degree of protection (NEMA)

Other

Height

125mm

Type of electrical connection of main circuit

Screw connection

Interlockable

With pre-assembled cabling

Type of control element

Long turning handle

Degree of protection (IP), front side

IP00