Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Mounting methodDIN rail (top hat rail) 35 mm
Construction size3 modular spacing
Short-circuit-proofNo
Max. continuous voltage AC550V
Signalling at the deviceOptic
Max. continuous voltage DC-V
Voltage protection level1.8kV
Nominal voltage AC480V
Voltage protection level L-N1.8kV
Max. conductor cross section flexible (fine-strand)16mm²
Max. conductor cross section solid (solid, stranded)25mm²
Integrated backup fuseYes
Nominal voltage DC-V
With remote signalling contactYes
Voltage protection level N-PE1.8kV
Nominal discharge surge current (8/20)20kA
Max. PV-voltage-V
Category type 2Yes
Type of poles3
System configurationOther
System configuration DCNo
System configuration TNNo
System configuration ITNo
System configuration TN-C-SNo
Number of conductors (without earthing)3
Max. overcurrent protection device, series connection (fuse)100A
System configuration TN-SNo
System configuration TN-CNo
System configuration TTNo
Max. discharge surge current (8/20)10kA
System configuration otherYes
Integrated short-circuit protection selective to fuse gG-A
Integrated short-circuit protectionNo
Max. overcurrent protection device, parallel connection (fuse)-A
Short-circuit breaking capacity (Isccr)100kA
Leakage-current freeYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB802344R3300 | OVR T2 2N 40-550 P TS U

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

3 modular spacing

Short-circuit-proof

Max. continuous voltage AC

550V

Signalling at the device

Optic

Max. continuous voltage DC

-V

Voltage protection level

1.8kV

Nominal voltage AC

480V

Voltage protection level L-N

1.8kV

Max. conductor cross section flexible (fine-strand)

16mm²

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated backup fuse

Nominal voltage DC

-V

With remote signalling contact

Voltage protection level N-PE

1.8kV

Nominal discharge surge current (8/20)

20kA

Max. PV-voltage

-V

Category type 2

Type of poles

3

System configuration

Other

System configuration DC

System configuration TN

System configuration IT

System configuration TN-C-S

Number of conductors (without earthing)

3

Max. overcurrent protection device, series connection (fuse)

100A

System configuration TN-S

System configuration TN-C

System configuration TT

Max. discharge surge current (8/20)

10kA

System configuration other

Integrated short-circuit protection selective to fuse gG

-A

Integrated short-circuit protection

Max. overcurrent protection device, parallel connection (fuse)

-A

Short-circuit breaking capacity (Isccr)

100kA

Leakage-current free