Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Width12.6mm
Height74.1mm
Depth55.4mm
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Time delay at signal exchange0.1 - 0.3ms
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Number of HW-interfaces RS-4850
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
With optical interfaceNo
Suitable for safety functionsNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Input current at signal 12mA
Type of voltage (input voltage)DC
Type of digital outputNone
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusNo
Short-circuit protection, outputs availableNo
Type of electric connectionScrew-/spring clamp connection
Appendant operation agent (Ex ib)No
Rail mounting possibleYes
Fieldbus connection over separate bus coupler possibleYes
Explosion safety category for gasNone
Output current0A
Explosion safety category for dustNone
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ia)No
Supporting protocol for DeviceNetNo
System accessoryYes
Supporting protocol for SUCONETNo
Wall mounting/direct mountingNo
Radio standard BluetoothNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Rack-assembly possibleNo
Front built-in possibleNo
Number of HW-interfaces Wireless0
Supporting protocol for Foundation FieldbusNo
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
IO link masterNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supply voltage AC 50 Hz0 - 0V
Supply voltage AC 60 Hz0 - 0V
Type of output voltageDC
Permitted voltage at input0 - 30V
Permitted voltage at output0 - 0V
Digital inputs configurableNo
Supply voltage DC18 - 30V
Certified for UL hazardous location class INo
Radio standard UMTSNo
Digital outputs configurableNo
SIL according to IEC 61508None
Supporting protocol for EtherCATNo
Radio standard GSMNo
Radio standard GPRSNo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location division 1No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location division 2No
Certified for UL hazardous location class IINo
Certified for UL hazardous location group A (acetylene)No
Number of digital inputs2
Number of digital outputs0
Voltage type of supply voltageDC
Degree of protection (IP)IP20