Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width131mm
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Height273mm
With control elementYes
Number of HW-interfaces other0
Number of digital inputs5
Number of digital outputs2
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of analogue outputs2
Number of HW-interfaces parallel0
With optical interfaceNo
Number of analogue inputs2
Depth204mm
Power consumption160W
Supporting protocol for ModbusYes
Supporting protocol for PROFIBUSYes
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Application in industrial area permittedYes
With PC connectionYes
Supporting protocol for SUCONETNo
Integrated breaking resistanceYes
4-quadrant operation possibleYes
Max. output at quadratic load at rated output voltage4kW
Application in domestic- and commercial area permittedYes
Max. output frequency500Hz
Number of phases output3
Number of interfaces PROFINET0
Number of phases input3
Max. output at linear load at rated output voltage4kW
Supporting protocol for Data-HighwayNo
Mains frequency50/60 Hz
Type of converterU converter
Supporting protocol for SERCOSNo
Mains voltage200 - 240V
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for DeviceNetYes
Nominal output current I2N18A
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)Other
Max. output voltage250V
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32018FB-A20C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

131mm

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Height

273mm

With control element

Number of HW-interfaces other

0

Number of digital inputs

5

Number of digital outputs

2

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of analogue outputs

2

Number of HW-interfaces parallel

0

With optical interface

Number of analogue inputs

2

Depth

204mm

Power consumption

160W

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for TCP/IP

Supporting protocol for ASI

Application in industrial area permitted

With PC connection

Supporting protocol for SUCONET

Integrated breaking resistance

4-quadrant operation possible

Max. output at quadratic load at rated output voltage

4kW

Application in domestic- and commercial area permitted

Max. output frequency

500Hz

Number of phases output

3

Number of interfaces PROFINET

0

Number of phases input

3

Max. output at linear load at rated output voltage

4kW

Supporting protocol for Data-Highway

Mains frequency

50/60 Hz

Type of converter

U converter

Supporting protocol for SERCOS

Mains voltage

200 .. 240V

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for DeviceNet

Nominal output current I2N

18A

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

Other

Max. output voltage

250V

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.