Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Height450mm
Number of digital inputs5
Width173mm
Depth240mm
Number of digital outputs2
Power consumption187.5W
Number of analogue outputs2
Number of analogue inputs2
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4851
Supporting protocol for CANYes
Supporting protocol for ASINo
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Type of converterU converter
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetYes
Number of phases output3
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for ModbusYes
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Degree of protection (IP)IP55
Supporting protocol for Data-HighwayNo
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
Mains voltage200 - 240V
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output frequency500Hz
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage7.5kW
Integrated breaking resistanceYes
Max. output at linear load at rated output voltage7.5kW
Application in industrial area permittedYes
Number of phases input3
Supporting protocol for PROFIsafeNo
Max. output voltage250V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)12
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N30A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32030FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Height

450mm

Number of digital inputs

5

Width

173mm

Depth

240mm

Number of digital outputs

2

Power consumption

187.5W

Number of analogue outputs

2

Number of analogue inputs

2

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

1

Supporting protocol for CAN

Supporting protocol for ASI

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for KNX

Type of converter

U converter

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Number of phases output

3

With PC connection

Supporting protocol for INTERBUS-Safety

Supporting protocol for Modbus

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Degree of protection (IP)

IP55

Supporting protocol for Data-Highway

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

Mains voltage

200 .. 240V

4-quadrant operation possible

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Max. output frequency

500Hz

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

7.5kW

Integrated breaking resistance

Max. output at linear load at rated output voltage

7.5kW

Application in industrial area permitted

Number of phases input

3

Supporting protocol for PROFIsafe

Max. output voltage

250V

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

12

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Nominal output current I2N

30A

Related products