Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height419mm
Power consumption264W
Width173mm
With control elementYes
Depth241mm
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of analogue inputs2
Number of digital outputs2
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of digital inputs5
With optical interfaceNo
Supporting protocol for ASINo
Number of HW-interfaces other0
Supporting protocol for CANYes
Supporting protocol for SUCONETNo
Number of HW-interfaces parallel0
Supporting protocol for Data-HighwayNo
Number of analogue outputs2
Supporting protocol for DeviceNetYes
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
4-quadrant operation possibleYes
Mains voltage200 - 240V
Mains frequency50/60 Hz
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Number of interfaces PROFINET0
Type of converterU converter
Supporting protocol for EtherNet/IPYes
Max. output frequency500Hz
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage11kW
Number of phases input3
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceYes
Number of phases output3
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Max. output at linear load at rated output voltage11kW
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IOYes
Supporting protocol for SERCOSNo
Supporting protocol for PROFIsafeNo
Nominal output current I2N46A
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Max. output voltage250V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32046FB-B20C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

419mm

Power consumption

264W

Width

173mm

With control element

Depth

241mm

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of analogue inputs

2

Number of digital outputs

2

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of digital inputs

5

With optical interface

Supporting protocol for ASI

Number of HW-interfaces other

0

Supporting protocol for CAN

Supporting protocol for SUCONET

Number of HW-interfaces parallel

0

Supporting protocol for Data-Highway

Number of analogue outputs

2

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

4-quadrant operation possible

Mains voltage

200 .. 240V

Mains frequency

50/60 Hz

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

With PC connection

Number of interfaces PROFINET

0

Type of converter

U converter

Supporting protocol for EtherNet/IP

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

11kW

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Number of phases output

3

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Max. output at linear load at rated output voltage

11kW

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for PROFIsafe

Nominal output current I2N

46A

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Max. output voltage

250V