  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width235mm
Height540mm
With control elementYes
Depth270mm
Number of digital inputs5
Power consumption345W
Number of digital outputs2
Number of analogue inputs2
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4851
Supporting protocol for KNXNo
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of analogue outputs2
With optical interfaceNo
Number of HW-interfaces RS-4220
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP55
Number of HW-interfaces industrial Ethernet0
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Number of HW-interfaces USB0
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Type of converterU converter
Number of phases output3
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
With PC connectionYes
Number of phases input3
4-quadrant operation possibleYes
Mains voltage200 - 240V
Max. output at quadratic load at rated output voltage15kW
Max. output at linear load at rated output voltage15kW
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Integrated breaking resistanceYes
Application in domestic- and commercial area permittedYes
Max. output frequency500Hz
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Max. output voltage250V
Supporting protocol for BACnetNo
Degree of protection (NEMA)12
Nominal output current I2N61A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32061FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

235mm

Height

540mm

With control element

Depth

270mm

Number of digital inputs

5

Power consumption

345W

Number of digital outputs

2

Number of analogue inputs

2

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

1

Supporting protocol for KNX

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of analogue outputs

2

With optical interface

Number of HW-interfaces RS-422

0

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Supporting protocol for other bus systems

Degree of protection (IP)

IP55

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Number of HW-interfaces USB

0

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Type of converter

U converter

Number of phases output

3

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

With PC connection

Number of phases input

3

4-quadrant operation possible

Mains voltage

200 .. 240V

Max. output at quadratic load at rated output voltage

15kW

Max. output at linear load at rated output voltage

15kW

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Integrated breaking resistance

Application in domestic- and commercial area permitted

Max. output frequency

500Hz

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Max. output voltage

250V

Supporting protocol for BACnet

Degree of protection (NEMA)

12

Nominal output current I2N

61A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.