Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height540mm
Number of analogue inputs2
Depth270mm
Supporting protocol for LONNo
With control elementYes
Width235mm
Number of analogue outputs2
Number of digital inputs5
Number of digital outputs2
Power consumption518W
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces other0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4851
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for KNXNo
Degree of protection (IP)IP55
Mains voltage200 - 240V
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Application in industrial area permittedYes
Max. output at linear load at rated output voltage18.5kW
Type of converterU converter
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Number of phases input3
Number of phases output3
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage18.5kW
Supporting protocol for Foundation FieldbusNo
4-quadrant operation possibleYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Nominal output current I2N72A
Max. output voltage250V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo
Max. output frequency500Hz
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32072FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

540mm

Number of analogue inputs

2

Depth

270mm

Supporting protocol for LON

With control element

Width

235mm

Number of analogue outputs

2

Number of digital inputs

5

Number of digital outputs

2

Power consumption

518W

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces other

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for SERCOS

Supporting protocol for other bus systems

With PC connection

Supporting protocol for KNX

Degree of protection (IP)

IP55

Mains voltage

200 .. 240V

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Application in industrial area permitted

Max. output at linear load at rated output voltage

18.5kW

Type of converter

U converter

Number of interfaces PROFINET

0

Integrated breaking resistance

Number of phases input

3

Number of phases output

3

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

18.5kW

Supporting protocol for Foundation Fieldbus

4-quadrant operation possible

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Nominal output current I2N

72A

Max. output voltage

250V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Max. output frequency

500Hz

Degree of protection (NEMA)

12

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.