Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet0
With control elementYes
Power consumption814W
Depth313.5mm
Number of digital inputs5
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Height865mm
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of HW-interfaces USB0
Width330mm
Number of digital outputs2
Number of HW-interfaces parallel0
Number of analogue outputs2
With optical interfaceNo
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Number of phases input3
Number of phases output3
Supporting protocol for ModbusYes
Mains voltage200 - 240V
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Degree of protection (IP)IP55
4-quadrant operation possibleYes
Supporting protocol for INTERBUS-SafetyNo
Type of converterU converter
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Supporting protocol for DeviceNetYes
Max. output frequency500Hz
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage75kW
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage75kW
Application in industrial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes
Nominal output current I2N150A
Degree of protection (NEMA)12
Supporting protocol for PROFINET IOYes
Max. output voltage250V
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32150FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces industrial Ethernet

0

With control element

Power consumption

814W

Depth

313.5mm

Number of digital inputs

5

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Height

865mm

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of HW-interfaces USB

0

Width

330mm

Number of digital outputs

2

Number of HW-interfaces parallel

0

Number of analogue outputs

2

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

With PC connection

Supporting protocol for KNX

Supporting protocol for other bus systems

Number of phases input

3

Number of phases output

3

Supporting protocol for Modbus

Mains voltage

200 .. 240V

Number of interfaces PROFINET

0

Integrated breaking resistance

Degree of protection (IP)

IP55

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Type of converter

U converter

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Supporting protocol for DeviceNet

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

75kW

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

75kW

Application in industrial area permitted

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Nominal output current I2N

150A

Degree of protection (NEMA)

12

Supporting protocol for PROFINET IO

Max. output voltage

250V

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Related products