Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height865mm
Power consumption945W
With control elementYes
Width330mm
Depth313.5mm
Number of analogue outputs2
Number of analogue inputs2
Number of digital outputs2
Supporting protocol for LONNo
Number of digital inputs5
With optical interfaceNo
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSYes
Degree of protection (IP)IP55
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Number of HW-interfaces other0
Mains voltage200 - 240V
Number of phases output3
Type of converterU converter
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Mains frequency50/60 Hz
4-quadrant operation possibleYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Application in domestic- and commercial area permittedYes
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage45kW
Max. output frequency500Hz
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Max. output voltage250V
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage45kW
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Application in industrial area permittedYes
Number of phases input3
Nominal output current I2N180A
Supporting protocol for BACnetNo
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32180FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

865mm

Power consumption

945W

With control element

Width

330mm

Depth

313.5mm

Number of analogue outputs

2

Number of analogue inputs

2

Number of digital outputs

2

Supporting protocol for LON

Number of digital inputs

5

With optical interface

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Supporting protocol for other bus systems

With PC connection

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for DeviceNet

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP55

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Number of HW-interfaces other

0

Mains voltage

200 .. 240V

Number of phases output

3

Type of converter

U converter

Number of interfaces PROFINET

0

Integrated breaking resistance

Mains frequency

50/60 Hz

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Application in domestic- and commercial area permitted

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

45kW

Max. output frequency

500Hz

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Max. output voltage

250V

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

45kW

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Application in industrial area permitted

Number of phases input

3

Nominal output current I2N

180A

Supporting protocol for BACnet

Degree of protection (NEMA)

12

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.