Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height1280mm
Number of digital outputs2
Power consumption1425W
Width330mm
With control elementYes
Number of digital inputs5
Number of HW-interfaces RS-4851
Number of analogue inputs2
Number of HW-interfaces USB0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Depth341mm
Number of analogue outputs2
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces industrial Ethernet0
Supporting protocol for PROFIBUSYes
Integrated breaking resistanceYes
Supporting protocol for CANYes
With PC connectionYes
Application in industrial area permittedYes
Type of converterU converter
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Number of interfaces PROFINET0
Supporting protocol for other bus systemsYes
Mains voltage200 - 240V
Supporting protocol for DeviceNetYes
4-quadrant operation possibleYes
Supporting protocol for ASINo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP55
Number of phases output3
Application in domestic- and commercial area permittedYes
Supporting protocol for KNXNo
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Number of phases input3
Supporting protocol for SUCONETNo
Max. output frequency500Hz
Max. output at linear load at rated output voltage75kW
Relative symmetric net voltage tolerance10%
Nominal output current I2N248A
Max. output voltage250V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage75kW
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFINET IOYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)12
Supporting protocol for PROFINET CBANo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-32248FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

1280mm

Number of digital outputs

2

Power consumption

1425W

Width

330mm

With control element

Number of digital inputs

5

Number of HW-interfaces RS-485

1

Number of analogue inputs

2

Number of HW-interfaces USB

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Depth

341mm

Number of analogue outputs

2

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

With optical interface

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for PROFIBUS

Integrated breaking resistance

Supporting protocol for CAN

With PC connection

Application in industrial area permitted

Type of converter

U converter

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of interfaces PROFINET

0

Supporting protocol for other bus systems

Mains voltage

200 .. 240V

Supporting protocol for DeviceNet

4-quadrant operation possible

Supporting protocol for ASI

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP55

Number of phases output

3

Application in domestic- and commercial area permitted

Supporting protocol for KNX

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Number of phases input

3

Supporting protocol for SUCONET

Max. output frequency

500Hz

Max. output at linear load at rated output voltage

75kW

Relative symmetric net voltage tolerance

10%

Nominal output current I2N

248A

Max. output voltage

250V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

75kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

12

Supporting protocol for PROFINET CBA

Related products