Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth204mm
Height273mm
Width131mm
Number of digital outputs2
Power consumption300W
Supporting protocol for LONNo
Number of HW-interfaces other0
With optical interfaceNo
Number of analogue outputs2
Supporting protocol for TCP/IPYes
Number of digital inputs5
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
With control elementYes
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Supporting protocol for PROFIBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Max. output frequency500Hz
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Mains voltage380 - 480V
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Max. output at linear load at rated output voltage7.5kW
Supporting protocol for SUCONETNo
Number of interfaces PROFINET0
Type of converterU converter
4-quadrant operation possibleYes
Integrated breaking resistanceYes
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Number of phases input3
Degree of protection (IP)IP20
Number of phases output3
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage7.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for PROFIsafeNo
Nominal output current I2N18A
Degree of protection (NEMA)Other
Supporting protocol for PROFINET IOYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-34018FB-A20C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

204mm

Height

273mm

Width

131mm

Number of digital outputs

2

Power consumption

300W

Supporting protocol for LON

Number of HW-interfaces other

0

With optical interface

Number of analogue outputs

2

Supporting protocol for TCP/IP

Number of digital inputs

5

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

With control element

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Max. output frequency

500Hz

Supporting protocol for INTERBUS-Safety

With PC connection

Mains voltage

380 .. 480V

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Max. output at linear load at rated output voltage

7.5kW

Supporting protocol for SUCONET

Number of interfaces PROFINET

0

Type of converter

U converter

4-quadrant operation possible

Integrated breaking resistance

Application in domestic- and commercial area permitted

Application in industrial area permitted

Number of phases input

3

Degree of protection (IP)

IP20

Number of phases output

3

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

7.5kW

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for PROFIsafe

Nominal output current I2N

18A

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET IO

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.