Technical specifications

Number of digital inputs5
Width173mm
Number of analogue inputs2
With control elementYes
Number of analogue outputs2
Height450mm
Depth240mm
Power consumption444W
Number of digital outputs2
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet0
4-quadrant operation possibleYes
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Number of interfaces PROFINET0
Type of converterU converter
Max. output frequency500Hz
Application in industrial area permittedYes
Integrated breaking resistanceYes
Max. output voltage500V
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage18.5kW
Degree of protection (NEMA)12
Relative symmetric net voltage tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Degree of protection (IP)IP55
Mains voltage380 - 480V
Number of phases output3
Number of phases input3
Max. output at linear load at rated output voltage18.5kW
Nominal output current I2N39A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-34039FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

5

Width

173mm

Number of analogue inputs

2

With control element

Number of analogue outputs

2

Height

450mm

Depth

240mm

Power consumption

444W

Number of digital outputs

2

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

0

4-quadrant operation possible

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

With PC connection

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Number of interfaces PROFINET

0

Type of converter

U converter

Max. output frequency

500Hz

Application in industrial area permitted

Integrated breaking resistance

Max. output voltage

500V

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

18.5kW

Degree of protection (NEMA)

12

Relative symmetric net voltage tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Degree of protection (IP)

IP55

Mains voltage

380 .. 480V

Number of phases output

3

Number of phases input

3

Max. output at linear load at rated output voltage

18.5kW

Nominal output current I2N

39A

Related products