Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width234mm
Depth261mm
Height485mm
Number of digital outputs2
With control elementYes
Number of digital inputs5
Power consumption925W
Number of analogue outputs2
Number of analogue inputs2
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Supporting protocol for ASINo
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSYes
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Mains voltage380 - 480V
Supporting protocol for SUCONETNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Number of phases output3
4-quadrant operation possibleYes
Application in domestic- and commercial area permittedYes
Type of converterU converter
Max. output at linear load at rated output voltage37kW
Number of interfaces PROFINET0
Application in industrial area permittedYes
Max. output frequency500Hz
Integrated breaking resistanceYes
Number of phases input3
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage37kW
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Max. output voltage500V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for BACnetNo
Nominal output current I2N72A
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-34072FB-B20C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

234mm

Depth

261mm

Height

485mm

Number of digital outputs

2

With control element

Number of digital inputs

5

Power consumption

925W

Number of analogue outputs

2

Number of analogue inputs

2

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Supporting protocol for ASI

With optical interface

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

With PC connection

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Supporting protocol for CAN

Mains voltage

380 .. 480V

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Number of phases output

3

4-quadrant operation possible

Application in domestic- and commercial area permitted

Type of converter

U converter

Max. output at linear load at rated output voltage

37kW

Number of interfaces PROFINET

0

Application in industrial area permitted

Max. output frequency

500Hz

Integrated breaking resistance

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

37kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Max. output voltage

500V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for BACnet

Nominal output current I2N

72A

Degree of protection (NEMA)

Other

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.