Width330mm
Height865mm
Power consumption1575W
Depth313.5mm
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of analogue inputs2
Number of HW-interfaces other0
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Number of HW-interfaces parallel0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of digital inputs5
Number of digital outputs2
With optical interfaceNo
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Number of analogue outputs2
With control elementYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsYes
Number of phases input3
Degree of protection (IP)IP55
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Type of converterU converter
Number of phases output3
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceYes
With PC connectionYes
Max. output frequency500Hz
Relative symmetric net frequency tolerance10%
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage75kW
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage75kW
4-quadrant operation possibleYes
Mains voltage380 - 480V
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Nominal output current I2N150A
Supporting protocol for Foundation FieldbusNo
Max. output voltage500V
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DA1-34150FB-B55C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

330mm

Height

865mm

Power consumption

1575W

Depth

313.5mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Number of analogue inputs

2

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of digital inputs

5

Number of digital outputs

2

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for Modbus

Number of analogue outputs

2

With control element

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Number of phases input

3

Degree of protection (IP)

IP55

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Type of converter

U converter

Number of phases output

3

Application in domestic- and commercial area permitted

Integrated breaking resistance

With PC connection

Max. output frequency

500Hz

Relative symmetric net frequency tolerance

10%

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

75kW

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

75kW

4-quadrant operation possible

Mains voltage

380 .. 480V

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Nominal output current I2N

150A

Supporting protocol for Foundation Fieldbus

Max. output voltage

500V

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

12